Return to previous page

Motor-driven pumps

SITEC motor-driven pumps with adjustable flow and with pressure control.

Specifications
Pressure max. 10.000 bar

Model A: Motor-driven pumps with adjustable flow 

Features and advantages

  • For the generation of pulsation-free and constant flow.
  • Controlled constant volumetric flows also at minimum flow ( control range 0.2–100%).
  • Prolonged constant flow due to large stroke capacity.
  • Hand operation ( pulse key forward and reverse) or automatic, continuous discharge flow.
  • Quick return to starting position and automatic reverse-to-forward motion. 
  • Pressure generator with servo motor and integrated multiturn encoder (resolution 15 Bit).
  • Teachable positions for reversing of movement and stroke limitations. Safety stroke limitations by inductive switches.
  • Control box 500x 500x300 mm (h x w x d) with 5.7" TFT touch panel ( indication of actual volumetric flow and position). Supply 230 VAC/ 50 Hz.
  • Digital interface for auto/man switch and analogue interface for set point (volumetric flow: standard configuration 4– 20 mA).
  • Analogue output for actual volumetric flow and piston position ( standard configuration 4– 20 mA).
  • All wetted parts in stainless steel and PTFE.

Options

  • Different analogue signals for external set point or actual value ( e.g. 0– 20mA or 0– 1 0 V ).
  • Model B : With pressure control.
  • Model C : Without controls.
  • Opposed-piston pump ( boxer).

Model B: Motor-driven pumps with pressure control

Features and advantages

  • Design like model A but with pressure control function.
  • To maintain a constant pressure in a high- pressure system.
  • Included equipment: pressure controller, pressure transducer, hand valves and check valve ( according to flow diagram).
  • Digital indication of piston position.
  • Digital interface for auto/man switch and start position  as well as analogue interface for set point ( pressure : standard configuration 4– 20mA).
  • Analogue output for actual pressure and piston position (standard configuration 4–20mA).

Option

  • Different analogue signals for external set point or actual value ( e.g. 0 – 20mA or 0– 10 V).

Model C: Motor-driven pumps without controls

Features and advantages

  • Assembled on a base plate with reduction gear box, servo motor and limit switches (an inductive limit switch on each end position).
  • Servo motor and integrated multiturn encoder (resolution 15 Bit).

Option